GTM Cartridge Filters PTFE Membrane
Maximum Operating Parameters
Differential Pressure
• Forward (in water) 50 psid (3.4 bard) 20 °C (68 °F)
• Reverse 40 psid (2.7 bard) at 20 °C (68 °F)
Operating Temperature 82 °C (180 °F) at 10 psid(0.69 bard) in water
Recommended Changeout Pressure 35 psid (2.4 bard)
Sanitization/Sterilization In-line Steam 135 °C (275 °F), 30 min, multiple cycles
For all elevated temperature procedures above, a stainless steel support ring is required.
Construction Materials
Filtration Media Dual Layered Polytetrafluoroethylene (PTFE) Membrane Polypropylene Membrane
Media Support Polypropylene
End Caps Polypropylene
Center Core Polypropylene
Outer Support Cage Polypropylene
Sealing Method Thermal Bonding
O-rings Buna, Viton® (or FKM), EP, Silicone, FEP Encapsulated Silicone, FEP Encapsulated Viton (or FKM)
Dimensions
Length 5 to 40 in. (12.7 to 101.6 cm) nominal
Outside Diameter 2.75 in. (7.0 cm) nominal
Filtration Area 7.0 ft2 (0.65 m2) per 10 in. length
GTM Filter Cartridges are designed for general purpose usewherever a hydrophobic membrane filter is required. Manufacturedwith inherently hydrophobic polytetrafluoroethylene (PTFE)membrane, these cartridges are designed for use in the filtrationof aggressive solvents, and as compressed gas and vent filters.These cartridges are found in the manufacturing processesof firms in multiple industries that require high quality, costeffective filter technologies. The cartridge surface area, filter coredesign, pleat configuration, and pleat packing density have beenoptimized to provide increased cartridge life resulting in lowerfiltration operating costs.