DPS Double Layered PES Cartridge FIlters
PNC Membrane Filter Cartridges are sterilizing grade cartridges with charged Nylon 6,6 membrane. The nylon membrane used in these cartridges is positively charged for enhanced retention of particles below the rated pore size of the filter. Nylon cartridges see broad service in sterile fill applications in SVPs and as bioburden management filters in LVPs. Media preparation and service liquid filtration are other common applications for this cartridge. Positively charged nylon is particularly suited for endotoxin removal in water systems. Nylon is also used for filtration of solvents because of its broad compatibility and low level of extractables. Positively Charged Nylon 6,6 Membrane
Maximum Operating Parameters
Differential Pressure
• Forward (in water) 50 psid (3.4 bard) 20 °C (68 °F)
• Reverse 40 psid (2.7 bard) at 20 °C (68 °F)
Operating Temperature 82 °C (180 °F) at 10 psid(0.69 bard) in water
Recommended Changeout Pressure 35 psid (2.4 bard)
Sanitization/Sterilization
Filtered Hot Water 90 °C (194 °F), 30 minutes, multiple cycles, max 3 psid forward flow
Autoclave 121 °C (250 °F), 30 min, multiple cycles
In-line Steam 135 °C (275 °F), 30 min, multiple cycles
For all elevated temperature procedures above, a stainless steel support ring is required.
Construction Materials
Filtration Media Nylon 6,6 Membrane
Media Support Polypropylene
End Caps Polypropylene
Center Core Polypropylene
Outer Support Cage Polypropylene
Sealing Method Thermal Bonding
O-rings Buna, Viton® (or FKM), EP, Silicone, FEP Encapsulated Silicone, FEP Encapsulated Viton (or FKM)
Dimensions
Length 5 to 40 in. (12.7 to 101.6 cm) nominal
Outside Diameter 2.75 in. (7.0 cm) nominal
Filtration Area 7.0 ft2 (0.65 m2) per 10 in. length